In medical device manufacturing and food contact material processing, the biocompatibility and bonding reliability of adhesives are the most critical considerations. Catheters, masks, sensors — every product that comes into contact with the human body or food requires an adhesive that delivers both strong bonding and long-term safety without releasing harmful substances.

ODAKE CT8888 Biocompatible UV Adhesive is a professional-grade solution designed for these demanding applications. It is a medium viscosity, fast-curing, one-component UV curing adhesive that has passed ISO 10993-5 biocompatibility testing. It can be safely used in medical devices and food contact applications, offering excellent flexibility, impact resistance, and a wide temperature range (-54°C to 180°C).

1. What Is Biocompatible UV Adhesive?

biocompatible UV adhesive is a UV-curable adhesive that has been validated through biological evaluation (such as ISO 10993-5 cytotoxicity testing) to have no cytotoxic effects on human tissue. It is primarily used in medical devicesfood contact materialswearable devices, and other applications with strict human safety requirements.

CT8888 is ISO 10993-5 certified and can be safely used in:

  • Medical catheters, masks, and sensor assemblies

  • Food contact grade transparent plastic bonding

  • Precision assembly of medical devices

2. Key Features of CT8888

Feature Benefit
ISO 10993-5 Certified Passed biocompatibility testing, no cytotoxicity — suitable for medical devices
Fast Curing UV fixture ≤5 sec (30mW/cm²); deep cure ≤60 sec
High Toughness Urethane acrylate system provides flexible, impact-resistant bonds
Wide Temperature Range -54°C to 180°C for demanding environments
Medium Viscosity 400-600 mPa·s (25°C), ideal for gap filling applications
One-Component No mixing required, easy to use
High Transparency Colorless to pale yellow, maintains appearance

3. Technical Specifications

Product Parameters

Parameter Value
Chemistry Urethane Acrylate
Appearance Colorless to pale yellow liquid
Composition One-component
Specific Gravity @25°C 1.02
Viscosity @25°C (mPa·s) 400-600
Curing Method UV / Visible Light
Shelf Life 6 months (unopened, 8-21°C)

Cured Physical Properties

Parameter Value
Hardness (Shore D) 62
Temperature Range -54°C to +180°C
Refractive Index 1.48

Cured Electrical Properties

Parameter Value
Dielectric Strength 25 kV/mm
Volume Resistivity 8.9×10¹² Ω·cm
Dielectric Constant @1-kHz 4.87
Dissipation Factor @1-kHz 0.02

Bonding Strength (Shear Strength, ISO 4587)

Substrate Result
Polycarbonate (PC) Substrate failure
Glass-Glass Excellent
PC-PVC Excellent

4. Curing Conditions

CT8888 cures rapidly under UV and/or visible light:

Curing Parameter Value
UV Fixture Time (6mW/cm²) ≤15 sec (Glass-Glass)
UV Fixture Time (30mW/cm²) ≤5 sec (PC-PVC)
Tack-Free Time (100mW/cm²) ≤20 sec
Deep Cure Time (100mW/cm², 1-3mm) ≤60 sec

Recommended Light Sources: Metal halide lamps, LED UV lamps

Curing Tips:

  • For optimal surface cure, use short wavelength (220nm-260nm) UV light

  • Curing speed depends on light intensity, spectral distribution, exposure time, and substrate transmittance

  • Suitable for gap filling applications (recommended ≤0.5mm)

Compatible Substrates:

  • Plastic to plastic bonding (PC, PVC, ABS, TPU, etc.)

  • Hard/soft PVC to polycarbonate

  • Various substrate surfaces

  • Medical device applications

5. Environmental Resistance

Temperature & Chemical Resistance Testing

Environment Temp 2H 24H 170H
Boiling Water 100°C 100%
Water Immersion 49°C 100% 100%
Water Immersion 87°C 100%*
Isopropanol Immersion 22°C 100%
Heat/Humidity 38°C 100%

* Substrate failure

Note: CT8888 maintains excellent bond strength under harsh conditions including boiling water, high temperature/humidity, and isopropanol exposure — suitable for applications requiring high temperature resistancewater resistance, and chemical resistance.

6. ISO 10993-5 Biocompatibility Certification

CT8888 has passed ISO 10993-5 in vitro cytotoxicity testing, one of the most authoritative biocompatibility standards in the medical device industry.

Certification Item Description
Standard ISO 10993-5:2009 — Biological Evaluation of Medical Devices — Part 5: Tests for In Vitro Cytotoxicity
Test Cell Line Mouse fibroblast L929
Test Result Grade 0 — no cytotoxic reactivity
Applicable Scenarios Medical devices in direct or indirect contact with human tissue

This means CT8888 can be safely used in:

  • IV catheter assembly bonding

  • Infusion tube connections

  • Anesthesia mask assembly

  • Pressure sensor sealing

  • Medical monitoring line fixation

7. Applications

CT8888 is suitable for the following applications:

Application Area Specific Use Key Advantage
Medical Devices Catheters, masks, sensors, IV catheter assembly ISO 10993-5 certified
Food Contact Materials Transparent plastic containers, food packaging assembly Safe, non-toxic
Consumer Electronics Smart wearables, camera modules, optical assemblies High transparency, high toughness
Automotive Electronics Sensor encapsulation, connector fixing Wide temperature range (-54 to 180°C)
Lighting & Optoelectronics LED lens bonding, backlight modules Refractive index 1.48, high transparency

8. Why Choose ODAKE CT8888 Biocompatible UV Adhesive?

Advantage Description
ISO 10993-5 Certified Biocompatibility validated — medical grade safety
Fast Curing ≤5 sec fixture, ≤60 sec deep cure
High Toughness Flexible, impact-resistant bonds for soft/hard substrates
Wide Temperature Range -54°C to 180°C for demanding environments
Medium Viscosity 400-600 mPa·s for gap filling applications
One-Component No mixing required, easy to use
Factory Direct In-house R&D and manufacturing, customization supported

9. Contact Us

For more information about ODAKE CT8888 Biocompatible UV Adhesive, technical specifications, ISO 10993-5 certification reports, sample testing, or custom solutions, please contact us for professional selection support.

ODAKE CT8888 Biocompatible UV Adhesive | Medical Grade UV Glue ISO 10993-5 Certified for Catheter Bonding

Request A Quote for Your Projects!

Share The Post Now:

Ask for Quote Now

We will arrange for a specialist to contact you immediately.